国产成人久久777777,2021最新国产精品网站,伊人久久婷婷五月综合97色,制服丝袜亚洲,久久中文字幕2021精品,极品国产一区二区三区,啪啪永久免费av,日韩欧美网址
聯系任務主
1 累計需求單數
¥20.0 累計需求金額
0 違規次數

請幫助找一下EP9的相關章節

懸賞
已托管
20.00
¥20.00
  1. 發布需求
  2. 藥智客交稿
  3. 任務主選稿中
  4. 選滿結束
  1. 任務結束
任務結束
交易模式:
多人中標
賞金分配:
計件,每個¥8.5,已選1個,還需要1個
具體要求:
1. EP9, 2.2.23. Atomic absorption spectrometry.......37 2. EP9, 5.10. Control of impurities in substances for pharmaceutical use.....723

補充需求:

  • EP9.0中原子吸收法檢測無機元素雜質的檢測限是什么?即LOD(2016-11-28 16:19)
2016-11-28 09:01
0條新稿件,點擊看看
  • 匿名

    ep9.1,請查收,可以長期合作,價格可談!

    附件:
    PDF 20223E.pdf
    PDF 51000E.pdf
    2016-11-28 16:07 IP:重慶 參與編號 # 舉報
    數據載入中....
    發言請遵守"七條底線",還可以輸入140個字
  • 匿名

    2.2.23. ATOMIC ABSORPTION SPECTROMETRY GENERAL PRINCIPLE Atomic absorption is a process that occurs when a ground state-atom absorbs electromagnetic radiation of a specific wavelength and is elevated to an excited state. The atoms in the ground state absorb energy at their resonant frequency and the electromagnetic radiation is attenuated due to resonance absorption. The energy absorption is virtually a direct function of the number of atoms present. This chapter provides general information and defines the procedures used in element determinations by atomic absorption spectrometry, either atomisation by flame, by electrothermal vaporisation in a graphite furnace, by hydride generation or by cold vapour technique for mercury. Atomic absorption spectrometry is a technique for determining the concentration of an element in a sample by measuring the absorption of electromagnetic radiation by the atomic vapour of the element generated from the sample. The determination is carried out at the wavelength of one of the absorption (resonance) lines of the element concerned. The amount of radiation absorbed is, according to the Lambert-Beer law, proportional to the element concentration. APPARATUS This consists essentially of: a source of radiation; a sample introduction device; a sample atomiser; a monochromator or polychromator; a detector; a data-acquisition unit. The apparatus is usually equipped with a background correction system. Hollow-cathode lamps and electrodeless discharge lamps (EDL) are used as radiation source. The emission of such lamps consists of a spectrum showing very narrow lines with half-width of about 0.002 nm of the element being determined. There are 3 types of sample atomisers: Flame technique A flame atomiser is composed of a nebulisation system with a pneumatic aerosol production accessory, a gas-flow regulation and a burner. Fuel- oxidant mixtures are commonly used to produce a range of temperatures from about 2000 K to 3000 K. Fuel gases include propane, hydrogen and acetylene; air and nitrous oxide are used as oxidants. The configuration of the burner is adapted to the gases used and the gas flow is adjustable. Samples are nebulised, acidified water being the solvent of choice for preparing test and reference solutions. Organic solvents may also be used if precautions are taken to ensure that the solvent does not interfere with the stability of the flame. Electrothermal atomisation technique An electrothermal atomiser is generally composed of a graphite tube furnace and an electric power source. Electrothermal atomisation in a graphite tube furnace atomises the entire sample and retains the atomic vapour in the light path for an extended period. This improves the detection limit. Samples, liquid as well as solid, are introduced directly into the graphite tube furnace, which is heated in a programmed series of steps to dry the sample and remove major matrix components by pyrolysis and to then atomise all of the analyte. The furnace is cleaned using a final temperature higher than the atomisation temperature. The flow of an inert gas during the pyrolysis step in the graphite tube furnace allows a better performance of the subsequent atomisation process. Cold vapour and hydride technique The atomic vapour may also be generated outside the spectrometer. This is notably the case for the cold-vapour method for mercury or for certain hydride-forming elements such as arsenic, antimony, bismuth, selenium and tin. For mercury, atoms are generated by chemical reduction with stannous chloride or sodium borohydride and the atomic vapour is swept by a stream of an inert gas into a cold quartz cell mounted in the optical path of the instrument. Hydrides thus generated are swept by an inert gas into a heated cell in which they are dissociated into atoms. INTERFERENCES Chemical, physical, ionisation and spectral interferences are encountered in atomic absorption measurements. Chemical interference is compensated by addition of matrix modifiers, of releasing agents or by using high temperature produced by a nitrous oxide-acetylene flame; the use of specific ionisation buffers (for example, lanthanum and caesium) compensates for ionisation interference; by dilution of the sample, through the method of standard additions or by matrix matching, physical interference due to high salt content or viscosity is eliminated. Spectral interference results from the overlapping of resonance lines and can be avoided by using a different resonance line. The use of Zeeman background correction also compensates for spectral interference and interferences from molecular absorption, especially when using the electrothermal atomisation technique. The use of multi-element hollow-cathode lamps may also cause spectral interference. Specific or non- specific absorption is measured in a spectral range defined by the band-width selected by the monochromator (0.2-2 nm). BACKGROUND CORRECTION Scatter and background in the flame or the electrothermal atomisation technique increase the measured absorbance values. Background absorption covers a large range of wavelengths, whereas atomic absorption takes place in a very narrow wavelength range of about 0.005-0.02 nm. Background absorption can in principle be corrected by using a blank solution of exactly the same composition as the sample, but without the specific element to be determined, although this method is frequently impracticable. With the electrothermal atomisation technique the pyrolysis temperature is to be optimised to eliminate the matrix decomposition products causing background absorption. Background correction can also be made by using 2 different light sources, the hollow-cathode lamp that measures the total absorption (element + background) and a deuterium lamp with a continuum emission from which the background absorption is measured. Background is corrected by subtracting the deuterium lamp signal from the hollow-cathode lamp signal. This method is limited in the spectral range on account of the spectra emitted by a deuterium lamp from 190-400 nm. Background can also be measured by taking readings at a non-absorbing line near the resonance line and then subtracting the results from the measurement at the resonance line. Another method for the correction of background absorption is the Zeeman effect (based on the Zeeman splitting of the absorption line in a magnetic field). This is particularly useful when the background absorption shows fine structure. It permits an efficient background correction in the range of 185-900 nm. CHOICE OF THE OPERATING CONDITIONS After selecting the suitable wavelength and slit width for the specific element, the need for the following has to be ascertained: correction for non-specific background absorption, chemical modifiers or ionisation buffers to be added to the sample as well as to blank and reference solutions, dilution of the sample to minimise, for example, physical interferences, details of the temperature programme, preheating, drying, pyrolysis, atomisation, post-atomisation with ramp and hold times, inert gas flow, matrix modifiers for electrothermal atomisation (furnace), chemical reducing reagents for measurements of mercury or other hydride- forming elements along with cold vapour cell or heating cell temperature, specification of furnace design (tank, Lvov platform, etc). METHOD Use of plastic labware is recommended wherever possible. The preparation of the sample may require a dissolution, a digestion (mostly microwave-assisted), an ignition step or a combination thereof in order to clear up the sample matrix and/or to remove carbon-containing material. If operating in an open system, the ignition temperature should not exceed 600 °C, due to the volatility of some metals, unless otherwise stated in the monograph. Operate an atomic absorption spectrometer in accordance with the manufacturers instructions at the prescribed wavelength. Introduce a blank solution into the atomic generator and adjust the instrument reading so that it indicates maximum transmission. The blank value may be determined by using solvent to zero the apparatus. Introduce the most concentrated reference solution and adjust the sensitivity to obtain a maximum absorbance reading. Rinse in order to avoid contamination and memory effects. After completing the analysis, rinse with water R or acidified water. If a solid sampling technique is applied, full details of the procedure are provided in the monograph. Ensure that the concentrations to be determined fall preferably within the linear part of the calibration curve. If this is not possible, the calibration plots may also be curved and are then to be applied with appropriate calibration software. Determinations are made by comparison with reference solutions with known concentrations of the element to be determined either by the method of direct calibration (Method I) or the method of standard additions (Method II). METHOD I - DIRECT CALIBRATION For routine measurements 3 reference solutions and a blank solution are prepared and examined. Prepare the solution of the substance to be examined (test solution) as prescribed in the monograph. Prepare not fewer than 3 reference solutions of the element to be determined, the concentrations of which span the expected value in the test solution. For assay purposes, optimal calibration levels are between 0.7 and 1.3 times the expected content of the element to be determined or the limit prescribed in the monograph. For purity determination, calibration levels are the limit of detection and 1.2 times the limit specified for the element to be determined. Any reagents used in the preparation of the test solution are added to the reference and blank solutions at the same concentration. Introduce each of the solutions into the instrument using the same number of replicates for each of the solutions to obtain a steady reading. Calculation . Prepare a calibration curve from the mean of the readings obtained with the reference solutions by plotting the means as a function of concentration. Determine the concentration of the element in the test solution from the curve obtained. METHOD II - STANDARD ADDITIONS Add to at least 3 similar volumetric flasks equal volumes of the solution of the substance to be examined (test solution) prepared as prescribed. Add to all but 1 of the flasks progressively larger volumes of a reference solution containing a known concentration of the element to be determined to produce a series of solutions containing steadily increasing concentrations of that element known to give responses in the linear part of the curve, if possible. Dilute the contents of each flask to volume with solvent. Introduce each of the solutions into the instrument, using the same number of replicates for each of the solutions, to obtain a steady reading. Calculation . Calculate the linear equation of the graph using a least-squares fit and derive from it the concentration of the element to be determined in the test solution. VALIDATION OF THE METHOD Satisfactory performance of methods prescribed in monographs is verified at suitable time intervals. LINEARITY Prepare and analyse not fewer than 4 reference solutions over the calibration range and a blank solution. Perform not fewer than 5 replicates. The calibration curve is calculated by least-square regression from all measured data. The regression curve, the means, the measured data and the confidence interval of the calibration curve are plotted. The operating method is valid when: the correlation coefficient is at least 0.99, the residuals of each calibration level are randomly distributed around the calibration curve. Calculate the mean and relative standard deviation for the lowest and highest calibration level. When the ratio of the estimated standard deviation of the lowest and the highest calibration level is less than 0.5 or greater than 2.0, a more precise estimation of the calibration curve may be obtained using weighted linear regression. Both linear and quadratic weighting functions are applied to the data to find the most appropriate weighting function to be employed. If the means compared to the calibration curve show a deviation from linearity, two- dimensional linear regression is used. ACCURACY Verify the accuracy preferably by using a certified reference material (CRM). Where this is not possible, perform a test for recovery. Recovery . For assay determinations a recovery of 90 per cent to 110 per cent is to be obtained. For other determinations, for example, for trace element determination the test is not valid if recovery is outside of the range 80 per cent to 120 per cent at the theoretical value. Recovery may be determined on a suitable reference solution (matrix solution) which is spiked with a known quantity of analyte (middle concentration of the calibration range). REPEATABILITY The repeatability is not greater than 3 per cent for an assay and not greater than 5 per cent for an impurity test. LIMIT OF QUANTIFICATION Verify that the limit of quantification (for example, determined using the 10 σ approach) is below the value to be measured.

    2016-11-28 16:02 IP:廣州 參與編號 # 舉報
    數據載入中....
    發言請遵守"七條底線",還可以輸入140個字

當前為付費需求,賞金分配方式:計件,合格一個支付一個。

發布者在發布需求時設定需要的稿件個數和單價,選標時在眾多參與中挑選合格的稿件,合格一個支付一個,即時到賬。

托管賞金,保證資金安全:

通過藥智網托管賞金,全面保障買家的資金安全。

買家先托管賞金到藥智網,藥智網擔保資金安全;買家對威客工作滿意后,再通知藥智網打款給威客。

流程說明:

發布需求

點擊“發布需求”按鈕,按照流程引導,將需求詳情、具體要求描述清楚,發布到藥智網的藥智匯平臺。

托管賞金

為征集到滿意稿件,任務主須做好“賞金預算”,并將賞金托管到藥智網指定賬戶,打消藥智客的顧慮,激勵藥智客積極參與需求挑戰。

藥智客參與

任務主托管賞金后,所發布的需求顯示“賞金已托管”字樣。只有托管了懸賞金的需求,能夠鼓舞眾多的藥智客參與,獲取到滿意的稿件!

選擇滿意合格

雇傭者會在眾多參與中選擇滿意的合格,合格一個支付一個,即時到賬。

類似的需求

    加載數據中...

該需求者還有這些需求

    加載數據中...

推薦需求

    加載數據中...
感興趣,就投稿吧!投的越早,中標幾率就越大! 收藏
挖掘醫藥數據,分享醫藥情報
掃一掃,關注藥智數據公眾號

2014 藥智再發力 我們換裝了??!

為了讓您有更好的體驗,藥智對用戶體系和產品進行了全新升級!

我要看看
主站蜘蛛池模板: 中文精品久久久久国产网址 | 国产成人午夜福利免费无码r| 国产va在线| 在线亚洲小视频| 园内精品自拍视频在线播放| 99色亚洲国产精品11p| 国产乱子伦视频三区| 日本91在线| 国产午夜一级毛片| 日本a级免费| 国产成人精品高清在线| www精品久久| 亚洲精品成人片在线播放| P尤物久久99国产综合精品| 精品视频一区二区三区在线播| 精品无码一区二区三区在线视频| 高清不卡一区二区三区香蕉| 国产乱肥老妇精品视频| 色亚洲激情综合精品无码视频 | 国产精品一区二区久久精品无码| 波多野结衣无码AV在线| 另类综合视频| 手机成人午夜在线视频| 国产永久无码观看在线| 色综合色国产热无码一| 欧美一级色视频| 日本精品视频| 欧美一级夜夜爽www| 亚洲精品午夜天堂网页| 麻豆国产精品视频| 干中文字幕| 国产福利在线免费| 国产交换配偶在线视频| 麻豆精品在线视频| 91精品啪在线观看国产60岁| 中文字幕第1页在线播| 欧美区日韩区| 影音先锋亚洲无码| 国产丝袜91| 欲色天天综合网| 国产免费怡红院视频| 国产亚洲欧美日韩在线一区| 最新痴汉在线无码AV| 久久久受www免费人成| 国产麻豆福利av在线播放| 国产精品美乳| 喷潮白浆直流在线播放| 一级毛片免费观看不卡视频| 国产亚洲高清在线精品99| 亚洲日韩第九十九页| 欧美日本在线播放| 午夜福利网址| 亚洲不卡网| 广东一级毛片| 欧美97欧美综合色伦图| 在线观看精品国产入口| 2022国产91精品久久久久久| 亚洲a级在线观看| 国产91小视频| 99一级毛片| 伊人久久婷婷| 日韩精品亚洲一区中文字幕| 91麻豆精品国产高清在线| 伊人91在线| 午夜人性色福利无码视频在线观看| 亚洲人成网址| a级毛片免费网站| 18禁不卡免费网站| 男人天堂亚洲天堂| 国产精女同一区二区三区久| 喷潮白浆直流在线播放| 久久99这里精品8国产| 欧美亚洲一区二区三区在线| 五月婷婷综合色| 国产欧美在线观看一区| 高清无码不卡视频| 71pao成人国产永久免费视频| 欧美在线网| 91区国产福利在线观看午夜| 精品人妻无码中字系列| 2020国产免费久久精品99| 天堂成人在线|